[ SÉRIE AVANCÉE ] - [ BAS VOLTAGE ]

Description

The Cristal Controls family of wall switch occupancy/vacancy sensors provides a simple and cost effective lighting control solution for many applications. Just like its line voltage counterpart, the low voltage Cristal Controls  0-10V dimming wall switch sensor is designed with contractors in mind. Less than 1” deep, the unit is 25-40% shallower than typical dimmers and sensors, resulting in less crowed wall boxes. CRISTALCONTROL products utilize the latest passive infrared technology and digital signal processing techniques to provide unmatched motion detection performance. These units are also available with an integrated microphone to provide overlapping passive acoustic occupancy detection for rooms with obstructions or where occupant motion is limited. For dimming adjustment, intuitive raise and lower buttons are present in addition to an on/off button.

Basic Operation

Sensors detect movement in the infrared energy that radiates from occupants as they move within the devices field-of-view. Once occupancy is identified, the sensor signals a connected power/relay pack to switch on the connected lighting. All units can also be configured to operate in Vacancy Mode (e.g., require lights be manually switched on). Once lights are on and if equipped with passive dual technology (PIR/Acoustic), the unit’s microphone is enabled to further enhance detection. An internal timer is set to keep lights on during brief periods of inactivity, and is reset every time occupancy is signaled by either the passive infrared or acoustic detection technologies. Ambient daylight detection can also be enabled in equipped units so that lights are held off in rooms with sufficient light contribution from windows or skylights.

Code Compliance

This wall switch sensor can be used to meet many requirements of ASHRAE 90.1 (2016), IECC (2015) and Title 24 (2016).

  • Occupancy Operation: Auto On/Auto Off
  • Vacancy Operation: Manual On/Auto Off
  • Partial On Operation:
    • Auto On to 50%
    • Users can raise or lower light level manually
    • Auto Off

Caractéristiques

Operating Voltage 12-24 VAC/VDC
Current Draw
Passive Infrared (PIR): 2mA
Dual Tech (DT) [PIR + Ultrasonic]: 10mA
Output Logic High VDC (Occupied Mode)
Dimming compatibility 0-10 VDC ballasts or drivers compliant with IEC 60929 Annex E.2
Dimming load – 50 mA (sink only)
Recommended Power Pack
CC-SWX-900 (for Stand Alone apps.)
CC-SWX-900-AX (for Multi-Way apps.)
Operating Temp 32°F to 122°F (0°C to 50°C)
Relative Humidity 0-95% Non-Condensing, Indoor Use Only
Size
2.74”H x 1.68”W x 1.39”D (6.96 x 4.27 x 3.53 cm)
Not Including Mounting Strap
Weight 4.5 oz
Mounting Single Gang Switch Box
Physical Features
  • Enclosure is 25-40% Shallower than Other Sensors (< 1” Depth into Wallbox)
  • Unique Bat-Wing Shaped Lens Provides Enhanced Peripheral Detection
  • Modern Look and Intuitive Easy-Tap Buttons for On/Off, Raise, & Lower
  • Rugged Vandal Resistant Lens
  • Settings are Adjustable Without Removing Cover Plate
Operational Features
  • Compatible with 0-10V Dimmable LED, and Fluorescent Lighting
  • Wall-To-Wall Passive Infrared Small Motion Detection
  • Passive Acoustic Detection (Optional) – Prevents False Offs when No Motion is Present
  • 100% Passive Detection Methods – No Interference Potential from External Devices
  • Configurable Sensor Settings Including Time Delays and Occupancy/Vacancy Operating Modes
  • Configurable Dimming Parameters including High/Low Trims, Turn on Levels, and Curve Types
  • Blue Locator LED when Lights are Off
  • Multi-Way/Multi-Sensor Option

Operational Modes

Cristal Controls wall switch sensors are intelligent devices that provide both excellent energy savings and enhanced user convenience.In stand alone models, users can choose from several pre-programmed operational modes that best fit their preferences and applicable energy codes. In multi-sensor/switch (-MS) models, Vacancy and Occupancy modes are achievable by configuration of the connected CC-SWX-900-AX power pack.

Vacancy Mode
  • Manual On / Automatic Off operation. Lights can also be switched off manually. This mode provides increased energy savings but requires the user to initially turn on the lights. Models CC-SWX-103, CC-SWX-104, CC-SWX-123, and CC-SWX-124 default to vacancy modes.
Occupancy Mode
  • Automatic On and Automatic Off operation. If lights are switched off manually, the Automatic On functionality is temporarily disabled to allow the person a few seconds to leave the room before switching back to Automatic On operation. However, if the person remains in the space the unit will stay in a manual on state until the switch is pressed again. This mode is the default operation of CC-SWX-101, CC-SWX-111, CC-SWX-121 and CC-SWX-131 models.
Automatic On w/ Exit Time Mode
  • Automatic On and Automatic Off operation. If lights are switched off manually, the Automatic On functionality is disabled for a fixed 30 seconds.
Override Off Mode
  • Automatic On and Automatic Off operation until lights are switched off manually, at which point Automatic On functionality is disabled until the switch is pressed again.
Disabled Switch Mode
  • Automatic On and Automatic Off operation only. Switch functionality to manually turn on/off lights is disabled.
Presentation Mode
  • If lights are switched off manually, the Automatic On functionality is disabled until the space becomes unoccupied and the sensor’s time delay expires.

Applications

A wall switch sensor is typically used in a small room or enclosed space. A Passive Infrared (PIR) only sensor is sufficient for spaces where line of site is maintained and occupants are periodically moving (e.g., copy rooms, storage rooms). Dual technology sensors are necessary where occupants may be partially blocked from the sensor’s direct view or where they may be stationary (e.g., private offices or restrooms with stalls).

  • Private Restrooms
  • Small Meeting Room
  • Storage Room
  • Copy Rooms
  • Small Office
  • Break Room
  • Restroom with Stalls
  • Vestibule

Ressources

Fiche technique

Fiche technique
English
886.08 kB

Produits Reliés