Skip to main content

Description

The Cristal Controls CCRC Zone Controller provides up to 4 control zones for standalone use or centralized use. Capable of switching up to 4 circuits of 20A they offer the possibility to control local or open areas.

Each zone can be individually controlled for dimming (0-10V) or on / off lighting zones. Easy to install, the CCRC controllers can be connected directly to the electrical conduit network without the need for a junction box. This powerful zone controller offers all the same functions whether it is used locally or in a network.

Operation

The default functions enable dimming and ON/OFF using a low voltage switch or occupancy sensor. Each zone can be preprogrammed at the factory to execute custom scenes. In addition, CCRC zone controllers have many programmable functions and parameters. Using an RS-485 USB interface and BACnet Browser software (free), the user can adjust the maximum lighting level, button functions, occupancy time, etc. In a centralized networked system, all controller can be modified by the building manager or the Cristal Controls master management system called Jasper. Using a planner, CCRC zone controller can easily be used to sweep ON and OFF an entire building. All parameters can be controlled remotely.

Features

Case type Nema 1 Surface, lockable Screw Cover
Dimensions 12 ’’ (height) x 12 ’’ (length) x 4 ’’ (depth)
Inputs 120/240/277/347Vac
Relay output
Main 20A Rated Relay 120/277/347
CULus Vac / by zone
Secondary: 1A 24Vdc / Vac / per zone
Dimming output 0-10V sink or source (100mA)
Universal entry 3 (1x occupancy detector, 2x buttons) / per zone
Analog input 1 (1x light detector) / per zone
Native communication
BACnet MSTP (RS845)
DALI
Operating environment
(0C to 50C)
Certification
CSA and UL assembly
  • Control up to 50x 0-10V fixtures per zone (sink or source type)
  • Maximum capacity of 20Amp per zone
  • Management of the contribution of natural brightness contribution by single or double zone
  • Specific light level adjustment according to the occupancy
  • Adjustable detection time by programming
  • Universal inputs for sensor and momentary low voltage switch
  • Timer and flick warning
  • Ability to record 16 preset scenes
  • Test Buttons for the Installer
  • HVAC system auxiliary contact
  • Native DALI and BACnetMSTP communication
  • UL508 / CSA assembly

Applications

The default functions enable dimming and ON/OFF using a low voltage switch or occupancy sensor. Each zone can be preprogrammed at the factory to execute custom scenes. In addition, CCRC zone controllers have many programmable functions and parameters. Using an RS-485 USB interface and BACnet Browser software (free), the user can adjust the maximum lighting level, button functions, occupancy time, etc. In a centralized networked system, all controller can be modified by the building manager or the Cristal Controls master management system called Jasper. Using a planner, CCRC zone controller can easily be used to sweep ON and OFF an entire building. All parameters can be controlled remotely.