Our solid state relay (SSR) is recommended for use with proportional temperature controllers and other applications where long life and solid state reliability are required. They provide ON-OFF control for any electrical resistance or HID lighting load.

The solid state relay control is suitable for all processes, that have either long or short-timed cycles. However, the shorter the cycle time, the better is your control.

ADVANTAGES

  • Modulates the power nearest to the demand and reduces energy costs and power consumption
  • Keeps the temperature closer to the desired set point for maximum comfort
  • Higher precision, superior than contactors
  • Fast adjustment and installation
  • Zero-crossing operation and silent arcless switching
  • Cycles once per second; very fast and quiet
  • No maintenance, due to less mechanical parts failure
  • Life expectation higher than 1 000 000 000 operations
  • Does not create RFI (radio frequency interference) and will not affect sensitive electronic equipment
  • Epoxy thermally protected, for humidity protection, overheat or contaminated environment protection

Features

Operation Zero-crossing
Current 6 à 1000A
Legs 1,  2, 3
Voltage 48V to 600VAC depending on model
Operating temperature -20°C to 45°C (-4°F to 113°F ) *over 25°C (77°F) need deratng
Storage temperature -40°C – 80°C
Power module Two SCR back-to-back
Heatsink Aluminium 6063-t5 1.56°/W/3in. – PER. 44″.
Control signal 3-32VDC, 24VAC, 120VAC on demande
Connection Screws & Tab 0.250″
Mounting Cover 4″ x 4″
Cover 4″11/16 x 4″11/16
4x mountng holes
Certification CSA Canada & US
Warranty Standard two years limited warranty

Applications

  • Resistive loads such as commercial duct heaters
  • Lighting control
  • Electronic boilers
  • Electronic humidifiers
  • Industrial & commercial ovens and furnaces
  • Mine heaters
  • Integrated circuit processing equipment
  • Temperature control
  • Replacement of magnetic or mercury contactors

Resources

SSR – Technical Data
CCS Model
Amps
Dimensions H” x W” x D” (without enclosure)
With Enclosure*
Quantity US Price
Spec sheet
CCT-30-1-S
6
3-1/32 x 2-5/8 x 7/8
N/A
82.00
EN
FR
CCT-15-1
15
2-1/8 x 4-3/4 x 2-5/8
A
49.00
CCT-15-1-C1
15
4 x 4-3/4 x 2-5/8
N/A
62.00
CCT-15-1-S
15
2-9/16 x 2-5/8 x 7/8
N/A
56.00
CCT-15-1-S-T
15
3-1/32 x 2-5/8 x 1-5/8
N/A
68.00
CCT-15-1-S-T240
15
3-1/32 x 2-5/8 x 1-5/8
N/A
100.00
CCT-15-3
15
6-1/2 x 4-3/4 x 2-5/8
A
197.00
CCT-15-3Y
15
8-1/2 x 4-3/4 x 2-5/8
A
297.00
CCT-25-1
25
2-1/8 x 4-3/4 x 2-5/8
A
58.00
CCT-25-1-C1
25
4 x 4-3/4 x 2-5/8
N/A
70.00
CCT-30-1
30
3-1/2 x 4-3/4 x 2-5/8
A
92.00
CCT-30-1-C2
30
4-11/16 x 4-3/4 x 2-5/8
N/A
100.00
CCT-30-3
30
6-1/2 x 4-3/4 x 2-5/8
A
218.00
CCT-30-3Y
30
8-1/2 x 4-3/4 x 2-5/8
A
322.00
CCT-40-1
40
6 x 4-3/4 x 2-5/8
A
213.00
CCT-40-3
40
8 x 4-3/4 x 2-5/8
A
353.00
CCT-40-3Y
40
10 x 4-3/4 x 2-5/8
A
493.00
CCT-45-1-C2
45
4-11/16 x 4-3/4 x 2-5/8
N/A
147.00
CCT-50-1
50
6 x 4-3/4 x 3
A
368.00
CCT-50-3
50
10 x 4-3/4 x 3
A
474.00
CCT-50-3Y
50
10-1/2 x 6-3/8 x 7-21/32
B
784.00
CCT-75-1
75
6 x 4-3/4 x 3
A
526.00
CCT-75-3
75
10 x 4-3/4 x 3
A
584.00
CCT-75-3Y
75
10-1/2 x 6-3/8 x 7-21/32
B
875.00
CCT-90-1
90
6 x 4-3/4 x 3
A
642.00
CCT-90-3
90
10 x 4-3/4 x 3
A
875.00
CCT-90-3Y
90
10-1/2 x 6-3/8 x 7-21/32
B
1312.00
CCT-135-1
135
7-1/2 x 6-3/8 x 7-21/32
B
757.00
CCT-135-3
135
7-1/2 x 6-3/8 x 7-21/32
B
983.00
CCT-135-3Y
135
12 x 6-3/8 x 7-21/32
E
1478.00
CCT-165-1
165
7-1/2 x 6-3/8 x 7-21/32
B
1014.00
CCT-165-3
165
12 x 6-3/8 x 7-21/32
C
1307.00
CCT-165-3Y
165
15 x 6-3/8 x 7-21/32
E
1906.00
CCT-200-1
200
7-1/2 x 6-3/8 x 7-21/32
B
1275.00
CCT-200-3
200
12 x 6-3/8 x 7-21/32
C
1748.00
CCT-200-3Y
200
15 x 6-3/8 x 7-21/32
E
2869.00
CCT-250-1
250
12 x 6-3/8 x 8-1/16
B
1452.00
CCT-250-3
250
15 x 6-3/8 x 8-1/16
C
2180.00
CCT-250-3Y
250
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
3269.00
CCT-300-1
250
12 x 6-3/8 x 8-1/16
C
1667.00
CCT-300-3
300
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
2451.00
CCT-300-3Y
300
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
3675.00
CCT-350-1
350
12 x 6-3/8 x 8-1/16
C
1884.00
CCT-350-3
350
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
2661.00
CCT-350-3Y
350
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
3994.00
CCT-400-1
400
15 x 6-3/8 x 9-1/2
C
2867.00
CCT-400-3
400
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
2867.00
CCT-400-3Y
400
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
4218.00
CCT-500-1
500
15 x 6-3/8 x 9-1/2
C
2267.00
CCT-500-3
500
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
3154.00
CCT-500-3Y
500
32 x 28-1/2 x 8-13/64
SEE DRAWINGS
4646.00
CCT-600-3
600
39 x 33 x 10-21/32
SEE DRAWINGS
C/F
CCT-750-3
750
39 x 33 x 10-21/32
SEE DRAWINGS
C/F
CCT-1000-3
1000
39 x 33 x 10-21/32
SEE DRAWINGS
C/F
* Enclosure Type A: 12 x 12 x 8 * Enclosure Type B: 16 x 12 x 12 * Enclosure Type C: 18 x 20 x 12 * Enclosure Type D: 5-1/2 x 9 x 4 * Enclosure Type E: 28 x 24 x 12-3/4 * C1: supplied with a 4″ x 4″ cover for installation onto a 4″ X 4″ electrical box. * C2: supplied with a 4-11/16″ X 4-11/16″ cover for a 4-11/16″ X 4-11/16″ electrical box.