Description

The CC-ONYX Room Controller is a powerful and flexible networked lighting control solution designed to meet the demands of modern commercial and institutional buildings. Supporting both standalone operation and seamless integration into networked lighting control systems, the CC-ONYX optimizes lighting performance, energy efficiency, and user comfort.

With built-in support for occupancy sensing, daylight harvesting, scene control, and BACnet integration, the CC-ONYX enables dynamic, intelligent control of two independent lighting zones — scalable to four zones when paired with an auxiliary controller. Designed for fast deployment and intuitive setup, it supports a wide range of modern control standards, including DALI, 0-10V dimming, BACnet MS/TP, and Bluetooth commissioning.

The CC-ONYX supports a wide range of control accessories such as sensors and wall switches, which can be connected either via standard wiring terminals or using RJ45 Quick Connect ports when paired with Cristal Controls “-QC” series accessories. This flexible wiring approach accelerates installation and reduces on-site errors.

Ideal for spaces such as classrooms, offices, conference rooms, and open-plan areas, the CC-ONYX controller delivers reliable and scalable lighting control within a compact footprint.

Features

  • Flexible deployment:
    • Operates as a standalone controller or as part of a networked system.
  • Built-in manual override:
    • Local ON/OFF control with LED status indication.
  • Quick configuration:
    • Select pre-programmed sequences using dipswitches, mobile app (Bluetooth), or via BACnet interface.
  • Scene control & demand response:
    • Supports custom lighting scenes, load shedding, and dimming level limits via BACnet or Bluetooth setup.
  • Dual wiring options for accessories:
    • Compatible with Cristal Controls Quick Connect (“-QC”) device via RJ45 ports , the controller is limited to operate in a single room with two zones in that configuration.
    • Also supports standard screw terminal wiring for traditional sensors and switches.
  • Plug-and-play connectivity:
    • RJ45 ports simplify low-voltage interconnections and device wiring.
  • Internal scheduler:
    • Onboard real-time clock enables time-based automation and control routines.
  • Ecosystem ready:
    • Fully compatible with existing Cristal Controls systems, sensors, and the Jasper building automation platform.
  • BAS integration:
    • Native BACnet MS/TP ensures interoperability with building automation systems.
  • Advanced dimming:
    • Two 0-10V outputs support tunable white and daylight-responsive control.
  • DALI-ready:
    • Full DALI-1 protocol support for addressable lighting applications.

Specifications

Supply 120–347VAC, 50/60 Hz
Dimensions (L x W x H) 228 x 139 x 53 mm [ 9” x 5.5” x 2.1” ]
Threaded Nipple Dimensions 2.54 cm, [ 1” (NPT) ]
Low Voltage Holes 3 x 19.05 mm, [ 3 x ¾” (NPT) ]
Surface Flange Fixations 4 x 4.2 mm holes for M4 screws, [ 4 x Ø 0.17” holes for #8 US screws ]
Relays Switching Capacity
2 x 120–277VAC, 20A Standard / Electronic ballast
2 x 347VAC, 16A Standard / Electronic ballast
Dimming Output 2 x 0-10VDC, (50 compatible sink drivers, maximum 10mA source drivers)
Dry Contact Inputs 8 x 10-24VDC, (Wall-switches, occupancy sensors, demand response, etc.)
Analog Inputs 2 x 0-10VDC, (Light level sensor, potentiometer, etc.)
Dry Contact Outputs 3 x 30VAC / VDC, 200mA
Supply Outputs 250mA
Buttons and LED Indicators 6
RTC Battery CR1220
Operating Temperature 0 °C to 40 °C [ 32 °F to 104 °F ], indoor use only
Storage temperature -40 °C to 85 °C [ -40 °F to 185 °F ]
Communications
BACnet MS/TP
DALI (2mA load)
Certifications
cULus listed / UL 916 / UL 2043 - (Plenum rated) / E218972
CSA C22.2 No. 205 - (Compliant)
FCC – part 15
ASHRAE 90.1 - (Compliant)
NECB - (Compliant)

Applications

  • Open Offices and Individual Work Areas
  • Corridors and Hallways
  • Parking Lots
  • Gymnasiums
  • Commercial offices
  • Schools
  • Amphitheatres
  • Stadiums
  • Multi-story buildings

Resources

Datasheet

Datasheet
English
1.14 MB
Datasheet
Français
1.25 MB

Promo

Promo
English
954.62 kB

Wiring diagram

Wiring diagram
Français
242.99 kB
Wiring diagram
Français
213.14 kB
Wiring diagram
Français
213.31 kB
Wiring diagram
Français
233.97 kB

Related Products

↑