Description

CC-WIXBEE GATEWAY

The CC-WiXBee gateway allows communication between the wireless nodes and the BACnet/IP network.

EXTERIOR LIGHTING

Ideal for outdoor lighting, with a plug conforming to ANSI C136.41 with 7 pins, it can support 0-10 VDC dimming.

WIRELESS RELAY

Autonomous wireless communicating modules to control, monitor and measure lighting devices in real time. In addition, digital and analog inputs and outputs make it easy to create an intelligent, distributed system. No wires to pass. Significantly simplifies control and automation projects. Much more advanced and rational than control panels, cable networks and motion detectors connected to electrical circuits. Cristal wireless control technology adapts perfectly to complex automation situations for simple, fast and economical commissioning. Communication is in a wireless mesh network, at 2.4 GHz Radio Frequency, ISM (Industrial, Scientific and Medical) certified.

Features

CC-WIXBEE GATEWAY

Protocol BACnet/IP
Supply 12 VDC, 10 Watts
Operating temperature 0°C to 70°C (32°F to 158°F)
Dimensions 6.5″ X 6.5″ X 1″
Outdoor antenna 2.4 GHz (24″) 9dBi N-type (default)
with 25 ″ cable coax 400 series (default)
Fixation DIN rail mountable
  • Website for network configuration.
  • Converting device values to BACnet objects.
  • Pre-wired and factory assembled, including pre-configured as required.
  • Maximum wireless range: 300 feet with standard relay or 1000 feet with pro relay.

EXTERIOR LIGHTING

Fixation ANSI C136.41 with 7 pins
Supply Same module for all voltage from 110 to 480VAC (+/- 10%), 50 & 60Hz, Less than 1 watt
Maximum charge 7A max (7A @ 120-240Vac, 5A @ 277-347Vac and 2A @ 480VAC)
0-10V dimming For all types of power supply and 0-10V ballasts and requires to be "sink" (up to 200mA) or "source" (20mA)
Measurement of electrical aggregates Amperage - Voltage - Power (2% margin of error), PF, operating hours counter.
0-10V dimming For all types of power supply and 0-10V ballasts and requires to be "sink" (up to 200mA) or "source" (20mA)
Standard entries Digital input for motion sensor or switch (max: 30V)
Ouputs 12V, max: 20 mA total
Ambient operating temperatures -40 ° C to + 70 ° C
Relative humidity Up to 99% non-condensing

WIRELESS RELAY

Supply L-N: 120, 277, 347 or L-L: 208-240, 480V (both 50 & 60Hz) (Voltage must be specified), 2 watts
Maximum charge 3 or 8 amps
Phase Angle Dimming Continuous retroactive
Measurement of electrical aggregates Amperage - Voltage - Power (2% margin of error), PF, operating hours counter.
Hi-Lo option HID lighting control (with a magnetic ballast with double value capacitors).
Dimming 0-10V Standard For all types of power supply and ballasts (Sink, up to 200mA) or (Source, 20mA live or more with external source)
Number of ballasts 3 ballasts max
Standard entries 3 digital (Motion sensor or switch (max: 48V)) + 2 analog inputs 0-10V
Ouputs 2 digital (up to 48V- Max: 20mA total)
Ambient operating temperatures -40 ° C to + 85 ° C
Relative humidity Up to 100% non-condensing (option of perfectly waterproof case)
  • Inputs for low voltage switch, motion and Lux sensor.
  • Compatible with all low voltage sensors and switches.
  • Respect of the guarantee for fluorescent lamps (100h without dimming).
  • Each module can be configured as a master and control many other slave modules.
  • Open collector outputs to control external loads.
  • Long range bidirectional wireless mesh network.
  • Unique individual addresses: 2 billion serial numbers.
  • Integration with Cristal Jasper BACnet or third party BMS.
  • Multiple groupings and scenarios.
  • Adjustable minimum and maximum dimming levels.
  • Programmable scenarios for after power failure situation.
  • Warning before switching off the light.
  • Both local and remote control with transmission of status reports and electrical measurements.
  • Manual ON/Auto-Off, Auto-ON/Auto-Off and grace period compliant

Applications

  • Car dealerships
  • Large parking lots
  • Grocery stores
  • Shopping centers

Resources

Datasheet

Datasheet
English
2.86 MB
Datasheet
Français
2.87 MB

Datasheet

Datasheet
English
1.04 MB
Datasheet
Français
492.51 kB

Datasheet

Datasheet
Français
1.58 MB
Datasheet
English
1.24 MB

Related Products