Description

L-DALI WIRELESS GATEWAY

The Cristal Controls L-DALI / BACnet gateway allows dimming and ON / OFF wireless relay control, while receiving a host of information. Using its LENO-801 interface, it allows the integration and control of all EnOcean equipment in North America.
The Cristal Controls L-DALI / BACnet gateway allows dimming and ON / OFF wireless relay control, while receiving a host of information. Using its LENO-801 interface, it allows the integration and control of all EnOcean equipment in North America.It is possible to integrate 1000 BACnet points and 100 Encoean products on the same interface.
It is also possible to see the battery level of the equipment using, the signal level received by the wireless equipment, the state of the wireless relays.

PTM-265 WIRELESS SWITCH

Echoflex wireless PTM-265 switches use a mechanical energy harvester that allow them to be powered by the touch of a finger and are completely battery-free, unlike wired switches. Echoflex wireless switches and sensors can be assigned to unlimited controller without restriction. On each controller, 20 switches or sensors can be assigned to create multi-input switching strategies for 3, 4 or up to 20 way switches. Wireless switches are available in white, black, ivory, brown and light almond. Wall plates sold separately.

CC-ERDRC-FCU WIRELESS CONTROLLER

Cristal lighing controllers use wireless technology to monitor the room’s environment. The CC/ERDRC controller can activate lighing loads with received input from a linked sensor or switch.
The CC/ERDRC- offers central command support to integrate with Building Management Systems gateways.
This controller is Range Confirmation on compatible, it works with the Resonate and “21” family of sensors to provide visual feedback of sensors signal strength in various locations for optimal sensor placement.
There are 3 ways to configure the controller which allows installers and facility operators to manage configuration settings without any tools, reducing call-backs and installation expense.

Features

L-DALI WIRELESS GATEWAY

Supply 120 Vca
Typical consumption 7.5W
Frequency 902.875 MHz
Operating temperature 0-40°C
Mounting on 35mm DIN43880 rail
Antenna pre-assembled in the case
Interface
BACnet/IP
BACnet/MSTP
http, ftp,
EnOcean (requires LENO-801)

PTM-265 WIRELESS SWITCH

Operating mode
On/Off
dimming
Supply Self-powered by actuation of the switch
Transmitting power 10mW EIRP
Emission range 100m (330ft) without obstacle, 24m (80ft) in an interior space
Radio frequency 902 Mhz by integrated antenna
Operating temperature -25 ° C to + 65 ° C (-13 ° F to 145 ° F)
Relative humidity 5% to 92% non-condensing
Weight 3 oz (85 grams)
Dimensions 115mm x 71mm x 20mm (4.5 "x 2.8" x 0.8 ")
Lifetime 50,000 cycles according to EN60669 / VDE0632
  • EnOcean EEP 05-02-02 switch for lighting and blind control
  • Radio frequency approved and approved according to FCC part 15.231 and IC RSS-210

CC-ERDRC-FCU WIRELESS CONTROLLER

Supply 120/277/347 VAC, 60 HZ
Consumption Full load 5.0W max.
Output power 24 VDC at 35mA
Inputs 24 VDC input
Buttons "LEARN" and "CLEAR" for assigning detectors
Ouputs N.O. relay rated 20A to 120 or 277 VAC, 15A to 347 VAC
Dimmable output 0-10 VDC à 25 mA maximum
Radio frequency 902MHz
Antenna Integrated flexible whisk
Transmission range 24 m (80 ft) - commercial office space (typical)
Operating temperature -10 ° C to 45 ° C (14 ° F to 113 ° F) (ambient)
Relative humidity 5% to 95% RH (non-condensing)
Weight 385g (13.5 oz)
Dimensions 91 x 48 x 49 mm (3.5″ x 1.9″ x 1.9″)
Mounting 1/2 ″ diameter mounting ferrule
  • Lighting circuit control with dimmable ballast control output (closed loop dimming option also available)
  • Integrated ambient light harvesting control with light capture mode
  • Presence-based lighting control with auto-ON / OFF or manual ON and auto-OFF using wired or wireless presence detectors
  • Controlled by wall switch without battery, light detector and presence detector
  • Range confirmation (patent pending) allows optimal positioning of linked detectors ("Resonate" and "21" series detectors only)
  • The central control support for BMS gateway control
  • Available at 902MHz - offering increased range and better resistance to interference
  • Easy installation on electrical junction box with 1/2 ″ diameter fitting
  • Double as a telegram repeater
  • CEC - title 24 compliant

Applications

  • Car dealerships
  • Large parking lots
  • Grocery stores
  • Shopping centers

Resources

Datasheet

Datasheet
Français
554.46 kB

Datasheet

Datasheet
English
124.82 kB
Datasheet
Français
73.78 kB

Datasheet

Datasheet
English
848.09 kB
Datasheet
Français
408.35 kB
* The products of this collection are not all present. Do not hesitate to contact one of our advisers for more information and to see the full range of products.

Related Products

↑